RE: [xl7] XL7 Pad velocity
2013-03-18 by Matt
... each preset of you turn the amp - velocity knob that will change the velocity of the pads. Only if that cord is set. Its all in cords. ... for playing
Yahoo Groups archive
Messages
Page 28 of 476 · 23796 messages matched
2013-03-18 by Matt
... each preset of you turn the amp - velocity knob that will change the velocity of the pads. Only if that cord is set. Its all in cords. ... for playing
2013-03-18 by craig ward
If you go into global there are settings for velocity curve and also for each preset of you turn the amp - velocity knob that will change the velocity of the
2013-03-18 by Matt
Turn midi off for 1-8.
2013-03-18 by Matt
... MIDI messages, but not the internal ones. Never tried it, but if it works that way, it s FAR better than pattern level settings and you are my hero, Matt.
2013-03-18 by Bruno
2013/3/18 Matt ... I definitely do, thanks for spotting! ... Not sure if it won t just turn off the specific channel for incoming MIDI
2013-03-18 by Matt
Research the patchcords your answer lies there
2013-03-18 by Matt
I think u mean external bruno. Also go into midi menu and turn midi for that channel off. ... have encountered some serious lag and hiccups while scrolling
2013-03-18 by raabje
I might have the answer: http://launch.groups.yahoo.com/group/xl7/message/19585 The pattern with my midi settings was more or less empty. Changing midi
2013-03-18 by raabje
hello group, One more. It seems to me that the pads of the XL7 aren t very sensitive for playing with different velocity. Notes sound more or less at the same
2013-03-18 by raabje
Hello group, A new XL7 owner here. Still bussy figuring out a lot of things. I want the XL7 to sequence external gear, track 1 to 7, and the rest 8 to 16 to
2013-03-18 by Bruno
Hi Jordan, 2013/3/18 jordan.sabie ... encountered some serious lag and hiccups while scrolling through the menu. Most likely it s the
2013-03-15 by steve_the_composer
Footnote: Here s the link to the discuss of FX Send patchords: http://launch.groups.yahoo.com/group/p2k/message/15887 . In short, the P2K presets seem to use
2013-03-15 by steve_the_composer
LOL! I didn t make the connection until you mentioned it. I assume you are referring to this thread: http://launch.groups.yahoo.com/group/p2k/message/15878 .
2013-03-15 by K2500X
Steve, aren t you having deja-vu? I had this exact problem a few weeks ago when we discussed it. There is clearly something wrong with the older versions of
2013-03-13 by Ricard
I experimented a bit more with this. The thud is definitely in the sample, and there s something weird going on in the amplifier envelope. With the release
2013-03-13 by steve_the_composer
Yeah. Syxer started out as being the first step in a sysex display/analyzer program (MS-DOS command line program). Every couple of years or so I tweak it.
2013-03-13 by Ricard
... I ll try out some more patches. At any rate they are a very definite improvement over the 2010 set. BTW, the program you ve used to manipulate the sysex
2013-03-13 by steve_the_composer
Thanks for testing them; glad they loaded OK. If you don t have arps in your user slots, just load some in or point it to an arp in one of your other ROMs. I
2013-03-12 by Ricard
... I rather think it s something else, for instance like you say below that there are references to non-existent resources in the files. The reason is that
2013-03-12 by steve_the_composer
PS: If the 2013 version of the banks work for you, I will delete the 2010 versions and reorganize the folder (reword the write up, get rid of the whole thing
2013-03-12 by steve_the_composer
Thanks for posting the XL-7 s sysex output. I explain it in the folder where you posted the output. Basically it is a whole bunch of cancel messages--I
2013-03-10 by Ricard
... In what way have they been problematic? I m not sure what you mean by Wear indicates performing well repeatedly. My XL-7 is actually a PX-7 in disguise.
2013-03-10 by Ricard
... Yes, that s the set. Although at the time it seemed that at least someone on the list tested it with success, which is why I think it s strange that I
2013-03-10 by Ricard
... Yes, I probably could, by sending the dump from one computer and capturing the MIDI output on another, if nothing else. I ll see when I can get around to
2013-03-10 by Matt
My worn unit px7 has not manifested any problems but my unworn units have been problematic. Wear indicates performing well repeatedly. ... My worn unit px7 has
2013-03-10 by steve_the_composer
I see that I posted a set in 2010. Is that the set you are having problems with? Based on the readme file, I see that I simply changed the ROM ID to point to
2013-03-10 by steve_the_composer
I am wondering if the outgoing midi out led is a sysex error message. Can you capture it? Where are the P2500 -- P2K ROM files? I will take a look to see if
2013-03-10 by Ricard
... At one point I was thinking of locating one of the E-Mu samplers that can perform sound authoring for the XL-7, and then dumping a bunch of classic drum
2013-03-10 by Ricard
... I would rather express it this way: At lower then maximum temperatures one can expect a higher number of write cycles than it says in the specification.
2013-03-10 by Ricard
... I agree. I think that s what they mean too. ... I m using a sysex dump program, so there s no tempo adjustment, however I can specify a delay between each
2013-03-09 by steve_the_composer
Thanks for the pointer to p. 168 of the XL-7 Manual. This parameter only affects sysex out. (See paragraph 1 below.) I believe the manual is talking about
2013-03-09 by Bruno
2013/3/8 Ricard ... XL-7 is transmitting data to a sequencer, not receiving? The manual says it influences both, but I have no detailed
2013-03-09 by Matt
... and ... terribly useful, and seem like they ve put them in just to fill up the available banks, the remaining 10% are really nice and on their own warrant
2013-03-09 by Bob S.
Just need someone with an SMT desoldering station and good SMT soldering skils.... Sent from my iPad ... Just need someone with an SMT desoldering station and
2013-03-09 by Bob S.
eBay, less than $10usd. Sent from my iPad ... eBay, less than $10usd. Sent from my iPad On Mar 8, 2013, at 8:09 PM, Royce wrote:
2013-03-09 by Royce
Hi Ricard ... You are right. Sorry about my mistake. I was also unaware that high temperature would reduce the write cycles. ... Absolutely, this is how I
2013-03-08 by Ricard
... No, I m not disappointed, while I must say that 90% of the sounds aren t terribly useful, and seem like they ve put them in just to fill up the available
2013-03-08 by Ricard
... I thought the sysex packet delay setting on the XL-7 is involved when the XL-7 is transmitting data to a sequencer, not receiving? /Ricard
2013-03-08 by Susan Subtract
No, it was defintely here. A veritable dissertation on 12 vs 16 knobs.
2013-03-08 by Bruno
Hi Richard, 2013/3/7 Ricard ... it sends an EOX (F7h). But even with a delay of one second for each EOX I still get the dreaded message
2013-03-08 by Ricard
... Yes, but it is soldered in place (56 pin TSOP package) so it requires surface mount soldering skills to replace it. Besides, I m not sure that the machine
2013-03-08 by Ricard
... In principle you are right. The flash chip in the XL-7 is an Intel E28F640, which has a minimum specified erase cycle count of 100,000. Note, it s not the
2013-03-08 by Matt
The controller assognments for the rack roms really arent that different and tbqh ur getting hooked up with an extra 4 controllers by using a command station.
2013-03-08 by steve_the_composer
I seem to recall a discussion recently about the 12-controller ROMs and the 16-controller ROMs and related issues. If it wasn t here, it was in the P2K User
2013-03-08 by Matt
Is the flash replaceable
2013-03-07 by Royce
Factory reset the unit first then try to load the file. Try another sysex file. If it stops in the same place or the factory reset takes a long time then you
2013-03-07 by Ricard
It seems that there s either an error in the files, or I m doing something very wrong. If I reboot the XL-7, it appears to load the patches up until patch 37
2013-03-07 by Ricard
I m trying to download the P2500-patches-for-Composer banks from the group files area to my XL-7. However, I keep getting Error! Code = 000 Sysex: too fast
2013-03-06 by Ricard
... Figures, although it would have been nice if the 12 knobs on the P2k were a subset of the 16 on the XL-7; i.e. 4 of the (least useful) knob assignments
2013-03-06 by Matt
True for all racks with 12 knobs