Re: [xl7] Trying to update to new O.S..........

2003-02-19 by kingof_birds <kingof_birds@yahoo.com>

--- In xl7@yahoogroups.com, "Jean Kergutuil" <jean.kergutuil@a...>
wrote:

> Note that the SYSEX PACKET DELAY parameter is NOT applicable to OS
> updates (nor to Sequence transfers when using E-Loader). 
[...]
> 
> YEAR !! but i have had the same problem when i tried to update to
new OS
> ... and when i set the sysex delay on 300 ms, that's solved my
problem !!
> and i wasn't the only one with this problem ...a friend advice me
to do
> this and it's works fine !

That's just some kind of coincidence (or voodoo). The code that does
MIDI packet delays is not even loaded while doing an OS update.
That's part of the 'main' OS. Duing OS updates you are running out of
the 'bootloader' OS (aka BIOS), a very small chunk of code that is
entirely separate from the main OS (it exists even if their is no
main OS in the machine at all) and that essentially only knows how to
load the main system out of FLASH (normal boot) and do OS updates.