> there\ufffds a bug connecting attack in Patchcords, > 1 LFO+ -> VolAtt or FiltAtt ->00 > 2 Midi M -> Cord Amount 1->-100 Try reordering those two cords. In general, cords that modify the amount of another cord should be placed in an earlier slot than the cord they're modifying. This is because the cords (unlike an analog synth) run sequentially instead of simultaneously. Most often this doesn't cause a problem, but in this case, by the time the second cord updates the first, the attack has already occurred. This also occurs with Vel->Amp, CC->CordAmt combinations, causing a blip of sound at low velocities before the cord kicks in. By the way, every synth quick has it's uses too. Because cords run sequentially, you can create "filters" with the patch bay with multiple cords, using the order of the cords as a delay element. You can also create "latching" cords to perform effects like sostenuto with the patchbay too. -Aaron > Thanx to Aaron, of course you`re right, freak Huh? =) __________________________________________________ Do you Yahoo!? Yahoo! Mail Plus - Powerful. Affordable. Sign up now. http://mailplus.yahoo.com
Message
Re: [xl7] Attack Bug
2003-02-04 by Aaron Eppolito
Attachments