Yahoo Groups archive

Emu XL-7 & MP-7 User's Group

Archive for xl7.

Index last updated: 2026-03-30 01:19 UTC

Message

Re: [xl7] Erratic Program Change !

2001-09-20 by Sean Wilhelmsen

Kamy,
Are using a Xl-1 environment, profile or preset list in your software sequencer?
What's happening is, your sequencer is sending bank selects that is are
not valid in the Xl-7. I ask if you are using the Xl-1 preset list
because, the Xl-1 has a different ID (MSB) than the XL-7. Though it may
seem like good idea, it will create this problem. The Xl-7 Rom Banks
are, MSB 14, LSB 0-3. User banks are always the same on all E-MU gear,
MSB 0, LSB 0-xx. Make sure you are sending the right MSB command for you
ROM as well. Pressing the Preset View Button and then Audition will give
you this information.

sean at e-mu / ensoniq 

kgilani@... wrote:
> 
> Hi
> 
> I get on XL-7's  LCD " preset (not installed) ", everytime I run my
> software
> sequencer with a preset from a ROM board, which I  ADDED to XL-7.
> 
> XL-7 completely recognize that board, but the preset jumps out
> everytime I
> run my software sequencer.
> Does anybody know what's the deal with it?
> 
> THX
> 
> Kamy
> 
>                    Yahoo! Groups Sponsor
>                        ADVERTISEMENT
>                           [Image]
> 
> 
> 
> To unsubscribe from this group, send an email to:
> xl7-unsubscribe@yahoogroups.com
> 
> Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

Attachments