I second that. I just uploaded all my sequences, just had to change sysex to 000 on both the mp-7 and eloader!! Thank god! No.... Thank Steve!!!!! So much worry gone just like that. All hail Steve the Composer, king of the Emus --- In xl7@yahoogroups.com, Aaron Eppolito <synthesis77@...> wrote: > > > Steve, you're awesome. Just thought I'd mention. > > > ----- Original Message ---- > From: steve_the_composer <smw-mail@...> > To: xl7@yahoogroups.com > Sent: Friday, April 10, 2009 7:34:34 PM > Subject: [xl7] Re: E-loader Help > > Update of e-loader "Get sequence" [transfer from E-Mu sequencer to computer] problem. > *If ID = 0, sequencer transfers. > *If ID > 0, transfer fails. > E-Mu sends songs packets 1 and 2 (universal system exclusive format). > e-loader (java console) reports a checksum error and sends NAK. > It looks like the the actual cs = the "should be" cs + sysex ID. > (In snippet 1, ID was 64; in snippet 2 ID was 5; in snippet 3 ID was 1.) > > CONSOLE SNIPPET 1: > bad checksum received. packetNum: 0 cs was: 117 should be: 53 > sending NAK > > CONSOLE SNIPPET 2: > bad checksum received. packetNum: 0 cs was: 48 should be: 53 > sending NAK > > CONSOLE SNIPPET 3: > bad checksum received. packetNum: 0 cs was: 127 should be: 126 > sending NAK > ------------------------------ > > SUGGESTION: > If "Get sequence" transfer fails: > (1) check sysex ID [E-Mu sequencer and e-loader] > (2) check for bad checksum error in java console [e-loader] > (3) if "was" cs - "should be" cs = sysex ID, change ID to 0. >