Thanks for figuring this out, Keith. I changed my copy of the manual. Interesting: it says "Exclusive Real-Time sub-ID#1 = 08h" in the description, but "Non-real time" in the format/example. The same discrepancy is in the section on Master Volume. (I'm guess that should also be real-time.) BTW, the error goes back at least as far as sysex manual 2.0. Kudos to you for finally correcting this!!! --Steve --- In xl7@yahoogroups.com, "Keith Young" <emigr8@...> wrote: > > I have just figured out the Single Note Tuning Change problem. The > manual is in error. It documents the message as a Midi Universal Non- > Realtime message (0x7e) when it should be Universal Realtime message > (0x7f). I have documented both these bugs in the SysExFaults file in > the P2K group file section. > > Thanks for the help, I thought I was cracking up for a while there. > Keith
Message
Re: Can anyone help with a Tuning Issue
2008-08-16 by steve_the_composer
Attachments
- No local attachments were found for this message.