Yahoo Groups archive

Emu XL-7 & MP-7 User's Group

Index last updated: 2026-04-09 23:09 UTC

Message

Re: Can anyone help with a Tuning Issue

2008-08-16 by steve_the_composer

Thanks for figuring this out, Keith. I changed my copy of the manual. 
Interesting: it says "Exclusive Real-Time sub-ID#1 = 08h" in the 
description, but "Non-real time" in the format/example. The same 
discrepancy is in the section on Master Volume. (I'm guess that should 
also be real-time.)

BTW, the error goes back at least as far as sysex manual 2.0. Kudos to 
you for finally correcting this!!!

--Steve 



--- In xl7@yahoogroups.com, "Keith Young" <emigr8@...> wrote:
>
> I have just figured out the Single Note Tuning Change problem. The 
> manual is in error. It documents the message as a Midi Universal Non-
> Realtime message (0x7e) when it should be Universal Realtime message
> (0x7f). I have documented both these bugs in the SysExFaults file in 
> the P2K group file section.
> 
> Thanks for the help, I thought I was cracking up for a while there.
> Keith