Aaron is (of course) right!!! Along with embedded sysex commands (see Files | E-Mu LAW), I played around with storing and playing back patch parameter sysex banks to external gear. (It was years ago, Casio CZ data if I remember correctly.) Also, you cannot edit sysex commands from the E-Mu sequencer. But the method Aaron describes (software sequencer --> e-loader --> E- Mu) does indeed work!!! --Steve --- In xl7@yahoogroups.com, Aaron Eppolito <synthesis77@...> wrote: > > Alas, the XL-7 cannot record sysex. It can, however, play back > sysex. That means that if you record the sysex into a software > sequencer and then push the file onto the XL-7 with E-Loader, you > can use the XL-7 to send out the sysex. > > -Aaron