I see. So that would mean that the pads themselves output very low voltages then. And are these low voltages comparable/within the same kind of range among SDS-III, V and SDS-7 pads ? In other words, can I get the same response from all 3 brains with all 3 kits indifferently ? On Wed, May 29, 2013 at 11:40 AM, jesper <jesper@...>wrote: > ** > > > Phil a skrev 2013-05-28 11:04: > > I quite agree with you. > > Now regarding sensitivity, ease of play, etc... are they all identical ? > Is > > it only a difference in looks ? > > And do they all output the same voltage ? I read somewhere that they go > > from 0 to 15V is that correct and true for all SDS-III, V & 7 pads ? > > It's far from voltages. The pad inputs are using far lower values. It's > the sequencer inputs that range from circa +3 to +15 depending on model. > The pads output millivolts up to 1,5 (If I recall correct). I bet > Wolfgang can tell you more. Some have limiting resistors in the pads and > some at the outputs of the brains etc. It's no clear science! ;) > > -- > electronically yours, jesper > > - -- --- ---- ----- ---- --- -- - > www.electronic-obsession.se > > [Non-text portions of this message have been removed]