2013-09-24 by Phil a

Thanks for your reply.
Maybe my measuring method is not correct, I will try to find some of these tools you recommend but what fact is I cannot get the envelope of my synth triggered properly when feeding it with the gate output of the DT, the envelope is lazy and weak, whereas when I send the gate output of a Minibrute for example into the same synth it triggers the envelopes perfectly, strong and clear, this is why I assumed that signal from the DT was too low.

Regarding the other question I will contact Christian next week then.

Thanks,
Phil


On Tue, Sep 24, 2013 at 9:33 AM, <yahoo@doepfer.de> wrote:
> Hi group,
>
>
> Dark TIme has this strange behaviour: the gate out signal seems
> low, sending around only 2 to 3V (probably 2,5V but my measuring
> tool is not accurate) when it should be sending 5V and around 5V
> when it should be sending 12V (jumper in the 12V position).
> Would anyone have any idea what could cause this ?
>
>
> Also, I noticed that in the "Update DT firmware" PDF page 2 first
> picture, 1 of the 2 jumpers circled in red (the one at the right
> ) is not in the same position as the one in my DT. The one in my
> DT is directly perpendicular to the left side of the other
> instead of being parallel to its right side.
> Should I correct this or this has nothing to do with the first
> issue and is not source of any other issue ?
>
>
> Thanks for your advices,
> Cheers,
> Phil

I cannot imagine that the Dark Time outputs only 2-3V Gate level. It
probably has to do with your measuring method. If you use a normal voltmeter
(e.g. a multimeter) you measure the average value of the high states (e.g.
+5V) and low states (0V) of the gate signal. If the pulsewidth is 50% you
will measure about 2.5V with your voltmeter. To measure the level of the
high state of the gate signal an oscilloscope is required. But you may
obtain a better result even with a simple voltmeter if you increase the
pulsewidth to the max. setting. Then you should read a value close to +5V
with your voltmeter (or +12V with the gate level jumper in the +12V
position).

Concerning you question about the update document I ask you to address this
question to our Dark Time specialist Christian Assall (software@doepfer.de).
But he is still on holiday until next week.

Best wishes
Dieter Doepfer



------------------------------------

Yahoo! Groups Links

<*> To visit your group on the web, go to:
http://groups.yahoo.com/group/Doepfer_a100/

<*> Your email settings:
Individual Email | Traditional

<*> To change settings online go to:
http://groups.yahoo.com/group/Doepfer_a100/join
(Yahoo! ID required)

<*> To change settings via email:
Doepfer_a100-digest@yahoogroups.com
Doepfer_a100-fullfeatured@yahoogroups.com

<*> To unsubscribe from this group, send an email to:
Doepfer_a100-unsubscribe@yahoogroups.com

<*> Your use of Yahoo! Groups is subject to:
http://info.yahoo.com/legal/us/yahoo/utos/terms/


Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.