AW: [Doepfer_a100] Dark Time low gate out signal

2013-09-24 by yahoo@doepfer.de

> Hi group,
>
>
> Dark TIme has this strange behaviour: the gate out signal seems
> low, sending around only 2 to 3V (probably 2,5V but my measuring
> tool is not accurate) when it should be sending 5V and around 5V
> when it should be sending 12V (jumper in the 12V position).
> Would anyone have any idea what could cause this ?
>
>
> Also, I noticed that in the "Update DT firmware" PDF page 2 first
> picture, 1 of the 2 jumpers circled in red (the one at the right
> ) is not in the same position as the one in my DT. The one in my
> DT is directly perpendicular to the left side of the other
> instead of being parallel to its right side.
> Should I correct this or this has nothing to do with the first
> issue and is not source of any other issue ?
>
>
> Thanks for your advices,
> Cheers,
> Phil

I cannot imagine that the Dark Time outputs only 2-3V Gate level. It
probably has to do with your measuring method. If you use a normal voltmeter
(e.g. a multimeter) you measure the average value of the high states (e.g.
+5V) and low states (0V) of the gate signal. If the pulsewidth is 50% you
will measure about 2.5V with your voltmeter. To measure the level of the
high state of the gate signal an oscilloscope is required. But you may
obtain a better result even with a simple voltmeter if you increase the
pulsewidth to the max. setting. Then you should read a value close to +5V
with your voltmeter (or +12V with the gate level jumper in the +12V
position).

Concerning you question about the update document I ask you to address this
question to our Dark Time specialist Christian Assall (software@doepfer.de).
But he is still on holiday until next week.

Best wishes
Dieter Doepfer

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.