Hi Florian and Dieter Thanks for the advice. Dieter, Florian also suggested in one message to power the Mean Well externally by adding a second power connector / switch in the rear panel so I can wire the Mean well to it. What do you think about it ? I think it could be easier than doing all the fuses deal. Thanks Ricardo --- In Doepfer_a100@yahoogroups.com, Florian Anwander <fanwander@...> wrote: > > Hi Ricardo / Dieter > > > Am 23.10.2012 16:36, schrieb yahoo@...: > > I think he is right. The Meanwell PSU is obviously a single PSU (i.e. one > > voltage output only, not two like the A-100PSU2). In this case the -V output > > of the Meanwell has to be connected to GND of the A-100 system. You may use > > e.g. a free GND terminal at the bus board. The +V of the Meanwell (= +5V) > > has to be connected to the unused +5V terminal of the A-100 bus board. > Thank you for the correction! > I have a +/-15V supply from Meanwell and was transfering the connection > info from there. > > I should have had a look at the datasheet before: > http://www.jameco.com/Jameco/Products/ProdDS/123290.pdf > At page 2 you can see that the 5Volts are between -V and +V. > > Florian > > -- > http://fa.utfs.org/ >
Message
Re: Please help! Installing +5v switch inside G6 case for firing up tube modules
2012-10-23 by ricardo
Attachments