Re: [Doepfer_a100] Re: A-190-2 front cv1 (note) seems to not work properly

2010-11-12 by Bakis Sirros

do you happen to have another module sending cv/gate signals to the same busboard?
(like the a185-1 or a185-2)
if yes, then you have to remove the jumper sending cv/gate signals to this busboard, from your 190-2 or from the other module.


Bakis Sirros - Parallel Worlds / Interconnected / Memory Geist

[Doepfer_a100] group owner

www. parallel - worlds - music. com

www. myspace. com/ parallelworldsmusic

www. myspace. com/ interconnectedmusic

www. myspace. com/ memorygeist

www. DiN. org. uk

www. musicamaximamagnetica. com

www. vu-us. com

--- On Thu, 11/11/10, contourmixer <contourmixer@yahoo.ca> wrote:

From: contourmixer <contourmixer@yahoo.ca>
Subject: [Doepfer_a100] Re: A-190-2 front cv1 (note) seems to not work properly
To: Doepfer_a100@yahoogroups.com
Date: Thursday, November 11, 2010, 7:37 PM







 



  


    
      
      
      

--- In Doepfer_a100@yahoogroups.com, <yahoo@...> wrote:

>

> > the back connection that goes to the buss send the right midi

> > note information but the front jack is an octave higher! and the

> > C# is a D, the D is an E and it just gets stranger from there on.

> > i know the unit is in V/Octave mode and am stumped any help

> > please? i did also try to tune the pot on the back as well with no luck

> 

> The internal bus CV and CV available at the front panel of the A-190-2 are

> hardwired. They are separated only by the jumper JP3. I cannot imagine how

> it's possible to get two different CVs. The trimming potentiometer is used

> to adjust the 1V/octave scale.

> 

> Best wishes

> Dieter Doepfer

>

if i take out JP3 it works fine in the front cv but if its in then the pitch in the front goes crazy again? ar they adding together? do i need to take out the jumper every time to use the font cv?

thanks in advance





    
     

    
    


 



  






      