thanks for the pointers, ingo. my first couple of plays on the a136 were a bit disappointing. sounds like i need to control the signal a bit more before it goes into this module to get the best results. regards, ian-c. ________________________________ From: Doepfer_a100@yahoogroups.com [mailto:Doepfer_a100@yahoogroups.com] On Behalf Of selfoscillate Sent: 11 November 2010 12:26 To: Doepfer_a100@yahoogroups.com Subject: Re: FW: [Doepfer_a100] a New month of modular patching ideas... > regarding the a136, a116, use them before the filter module, after the osc's (pretty obvious i know). i recommend to use a filter or a vca/mixer/attenuator in front of the a136 (especially when the filter lowers the amplitude of the signal). the a136 is very sensitive and has no attenuator at the signal input. if your input signal is too hot (like an unattenuated mix of vco waves) you will probably just get square waves out of the a136. not that this would sound bad, but it will not show the real capabilities of the a136. modulating the signal amplitude before the a136 can be more interesting than modulating the settings of the a136 itself. two filters are even better, one before and one after the a136. by the way, the cv inputs of the a136 also don't have attenuators (the corresponding knobs are disabled when a plug in inserted into the cv inputs), so an external attenuator is the best friend of the a136. best wishes ingo Click here<https://www.mailcontrol.com/sr/wQw0zmjPoHdJTZGyOCrrhg==> to report this email as spam. ********************************************************************** Serck Controls Ltd, Rowley Drive, Coventry, CV3 4FH, UK A company registered in England Reg. No. 4353634 Tel: +44 (0) 24 7630 5050 Fax: +44 (0) 24 7630 2437 Web: www.serck-controls.com Admin: post@serck-controls.co.uk A subsidiary of Schneider Electric. ********************************************************************** This email and files transmitted with it are confidential and intended solely for the use of the individual or entity to whom they are addressed. If you have received this email in error please notify the above. Any views or opinions presented are those of the author and do not necessarily represent those of Serck Controls Ltd. This message has been scanned for malware by Mailcontrol. www.Mailcontrol.com [Non-text portions of this message have been removed]
Message
RE: FW: [Doepfer_a100] a New month of modular patching ideas...
2010-11-12 by Ian Campbell
Attachments
- No local attachments were found for this message.