> on the 410 triple filter, i understand what the rate and depth controls do
> vis-a-vis the lfo and how it interacts with the filters but where does the
> "sweep" control fit in? what does it actually control?
It is a master sweep for all 3 filter sections. It moves them all ∗up∗ in
frequency together
as a group.
> why only 2 lfo`s and not go all the way and use 3 ?
Because 3 sounds really bad!
> ( i`ve noticed that these triple vcf modules seem to have elicited some
> interest from the modular user community since i`ve seen at least three
> manufacturers that offer them for their systems. i`ve gang patched
multiple
> vcf`s before over the years but never thought of it as a single module.
is
> it interesting enough to acquire or would someone be better off with with
> multiple single vcf`s ? )
Most VCFs do not offer high-Q bandpass as a filter type.
Paul S.