> 1. filters like the 420/440/480 CAN mix CV signals?Only on the CV ("FM") side. You ∗cannot∗ pass CVs ∗through∗ the filter (kind of
> 2. the motm-110 vca can NOT mix/process CV signals?Well, it's AC coupled. You need a MOTM-190 for a DC coupled VCA.