Thanks for all the recommendations.
That sounds like overkill all right. If the runty anachronism that I picked
up for a tenth of that doesn't do the trick, I'll look into one of these.
Cheers
Max
On 4/24/04 1:49 AM, "Paul Schreiber" <synth1@...> wrote:
> You need a counter with a 'reciprocal time base'. Instead of gating/counting
> pulses, it measures the ∗period∗ of the waveform and ∗calculates∗ the
> frequency.
> In typical MOTM overkill fashion, I use a Philips/Fluke model PM6666 counter
> which can measure down to 0.001Hz :) and at 0.1Hz resolution make 1,000
> measurements/sec :))
>
> This is a 10yr old model, I paid about $900 new but eBay has them every now
> and
> then for like $350.
>
> Paul S.