Archive of the former Yahoo!Groups mailing list: MOTM

previous by date index next by date
previous in topic topic list next in topic

Subject: Re: [motm] +5V in the 500 Series

From: Simon <simon@...>
Date: 2002-09-03

At 11:00 PM -0500 1/9/02, Paul Schreiber wrote:
>c) auto-power switch: the +15V turns on the +5V

What happens if there is no +5V power when the 15V turns on, does the
module get damaged at all?


>There is 1 more solution: a 3U wide MOTM-950 Supply. It's got all 3
>voltages BUT the +-15V is
>lower current: 400ma instead of 800ma. This is used to power 500
>Series ONLY. The 500 Series
>would use a 6-conductor MTA-156. The +5V is rated at 2A. This could
>power between 5 and 8 500
>Series.
>
>Thoughts??!?

How about a new larger current full size power supply that could
power the same number of both old and/or new modules.

Maybe it could have normal connectors for +- 15V to old and new
modules, with a separate 5V connector/wiring scheme for the new
modules.

This way people with existing power supplies could add the walwart
solution to their system, and people buying new supplies could just
buy the new supply and not have to deal with a messy power system
using two separate power cables/switches/etc. per cabinet.

And while you are designing a new supply, could you please add remote
on/off capability, so that we could use a non-powered front panel
switch if we want to. The remote part of the circuit could be
jumpered so that it could work as either a normal rear panel or
remote/front panel switched system. It could also have power status
lights on the front panel for the DC power rails/AC power/standby/etc.


Simon
Canberra