Archive of the former Yahoo!Groups mailing list: MOTM

previous by date index next by date
  topic list next in topic

Subject: Max. Frequencies

From: "Tentochi" <tentochi@...>
Date: 2001-05-17

LFO1 (320)26.8 Hz
LFO2 (320)27.8 Hz
VCO1 (300)96.8 kHz
S&H1 (100)13.2 Hz
S&H2 (101)12.3 Hz
VCF4 (410)not measured

Didn't want to take the time to find a way to measure '410 LFO frequency.

I didn't have the patience to find minimum frequencies. Slow! Slow! Slow!
Yeah!

These are all unmodulated.

These are all actually reading from my setup.

All measurements performed with Fluke 87-III.

Easy to do bit-descimation (simulated sampling effects) with VCO into S&H
since you can trigger it at sampler rates (i.e. 44.1 and 48 kHz).

Not possible to use un-modulated LFO to generate modulation source for
"growl" in brass patches (usually around 80 Hz) required. Hate to waste a
VCO on this.

--Shemp