Thanks Michael for the info. It is as I thought. Interesting tho
in the unit I have that they have chosen to connect the primary voltage
between pink 220V and brown 100v. This would give a differential of 120v which at 115v would give a slight undervoltage at the secondaries.
and thus increase the tranny current slightly.
Using the white 110v and Black 0v as u suggest would have been a better
choice. The Secondary voltage would be a tiny bit higher but it wouldn't be a big deal as the voltage regulators would have handled this fine.
If anyone is after technical help on things , please ask away as I am happy to help on any electronic questions and will do my best to answer them
Thanks again
Richard
--- In Simmons_Drums@yahoogroups.com, "Michael Buchner" <buchnerelectronics@...> wrote:
>
> I forgot: Replace the fuse by 1A type.
>
> [Non-text portions of this message have been removed]
>