Hm, that sounds like a pot with a cracked element. It will have to be replaced, unfortunately. You need to measure from the middle pot pin to ground to see the -5 to +5 volts. Crow /**/ On Tue, 14 Sep 2004 dizz@elitemofo.com wrote: > Crow, > > After cleaning the pot out with some contact cleaner the problem has > improved by appr. 50%. I believe it just hadn't been used in a while. > I finally got a decent DMM and measured the voltage on the pot. > However, I don't see any negative voltage unless I reverse the leads. It > reads 0V at minimum and sweeps up to 9.92V at the max rotation. In the > trouble spot, the meter reads "overload" briefly and quickly continues > measuring correctly after resuming the rotation. Any suggestions would > be greatly appreciated! > > dizz
Message
Re: [PolySix] VCF cutoff quirkiness
2004-09-14 by The Old Crow