First thing is to check on which module the problem is. With the DVM measure at KLM-367/IC7/pin1 (obtain GND at KLM-367/TP3). Now turn the EG-intensity knob. The voltage should go from -5V to +5V. If it does then KLM367 is OK and the fault is on KLM-366. If it does not the problem is on KLM-367 and/or KLM-370 Make this measurement and post the result. Johannes On 27.09.2014 04:49, Robert Fantinatto robertfantinatto@rogers.com [PolySix] wrote: > > > Hello! I recently had my KLM-367 board repaired and all is working well > except for the EG Intensity, it has no effect... > > Can anyone suggest where to look? I'm pretty handy with a multimeter > and oscilloscope... > > > >
Message
Re: [PolySix] EG Intensity knob not working
2014-09-27 by Johannes Hausensteiner