- LFO = if the LED still active and must be changed IC21 13600 De : PolySix@yahoogroups.com [mailto:PolySix@yahoogroups.com] De la part de Malte Rogacki Envoyé : samedi 10 novembre 2012 21:57 À : PolySix@yahoogroups.com Objet : [PolySix] Re: Polysix restoration: LEDs, Sub-Osc LFO issues. In my opinion this particular error is probably unrelated to the previous problems. If you look at the schematic you'll notice that those parameters are not controlled via the D and P lines on CN06; instead the are multiplexed and passed via CN11. Could indeed be a 4051 or one of its lines acting up. [Non-text portions of this message have been removed]
Message
RE: [PolySix] Re: Polysix restoration: LEDs, Sub-Osc LFO issues.
2012-11-10 by philippe.69