Re: (new) KLM-367 Calibration

2010-09-13 by Daniel A

Andy,

Here are the readings for T3

With Freq set to 0 the left Base (pin1) reads at approx +4.95v
With Freq set to 10 the left Base (pin1) reads at approx +4.95v (ie.. no change)

With VR5 fully counter clockwise the Emmitter (pin3) is reading at a slightly higher voltage then the base I would say approx +5.2v
And I get the same exact reading when I rotate VR5 fully clockwise.

I did do a reading on pin 16 of IC21 and I am getting -15v

- Daniel

--- In PolySix@yahoogroups.com, Andrew Jury <andy@...> wrote:
>
> OK then, so what is the voltage reading on the left-hand base of T3 with the
> MG frequency pot at 0 and at 10? Also what is the emitter voltage at with
> VR5 fully clockwise/counter clockwise? The tricky part is that the frequency
> is determined by the current input at IC21 pin 16, which isn¹t so easy to
> measure. But the voltages into the circuit might give us some clues...
> 
> Cheers,
> A
>