OK then, so what is the voltage reading on the left-hand base of T3 with the MG frequency pot at 0 and at 10? Also what is the emitter voltage at with VR5 fully clockwise/counter clockwise? The tricky part is that the frequency is determined by the current input at IC21 pin 16, which isn¹t so easy to measure. But the voltages into the circuit might give us some clues... Cheers, A On 12/09/2010 04:07, "Daniel A" <apophis93@yahoo.com> wrote: > > Andy, > > yes I am getting the voltage shift from what looks like -4.95 to +4.95. So > that is correct it appears. My 4.80v estimation was when I had the setting at > 10 as the manual states for MG calibration. But it does behave as you > described > > - Daniel > [Non-text portions of this message have been removed]
Message
Re: [PolySix] Re: (new) KLM-367 Calibration
2010-09-13 by Andrew Jury
Attachments