Peter, The act of you placing your DVM probes in-circuit is changing the eletrical characteristics of it. Hence, the changes in the sound. Did you I hear you right? Did you just say that the MG, PWM and effect frequency controls aren't working either?! If so I would be looking for disconnected tracks on the KLM-367 as a priority! I'll get you some comparisons after the weekend. Have a good one, Andy If you'd rather take this topic offline rather than bothering all these good people with this lengthy topic then please be my guest. We can post the answer when we have it! --- In PolySix@yahoogroups.com, "hjulskov" <hjulskov@...> wrote: > > Here are my measurements: > > 5: -9.90v > 6: -9.92v > 7: -8.55v > > Also I discovred an interresting thing -voice 3 + 5 are slightly > distorted -sounds like mg (running at a high frequency) is applied, > but frequency does not change when changing MG, PWM or effect > frequency. Also when probing pin 6 on IC17 all voices are distorted in > a similar way. > > /Peter > > > > --- In PolySix@yahoogroups.com, "Andrew Jury" <andy@> wrote: > > > > Hi Peter, > > > > Your P6 problem is really starting to bug me! Could you take a > > voltage measurement from IC17 between pins 5, 6, and 7 and ground? It > > will be interesting to see what is going into the mux. > > >
Message
Re: Suddenly out of tune -but still problems after changing PC-1 and R93
2008-08-22 by Andrew Jury
Attachments