2000-01-26 by Dave Bradley

> What is the difference between the 300 and the Micro VCO
> expected later this year?

300 - 2 units wide, 4 simultaneous output waveforms, hard sync and soft
sync, pulse width modulation, super accurate tracking and pitch stability,
linear and exp. fm.

310 micro vco - 1 unit wide, less expensive, not quite as accurate tracking
but still great, 2 waveform outputs, a triangle and a variable which can be
voltage controlled from a sawtooth to a square.

Attached is a panel mockup image I made at the time, as a result of the
discussion on this list.

Dave Bradley