>I've finished my MOTM-101 noise/s&h, and the clock range seems a bit >too low. According to the specs it should be 0.1 - 20 Hz typical, but >I measure 0.4 .. 13.7 Hz. Which I think is a bit off, to be within >the 'typical' range. :-) It's probably the pot (VR2) that is the problem. Most pots are only good to within 20%. There's not much you can do to increase the pot's maximum resistance (which affects the lowest frequency of the internal clock), but you can change R23 to compensate. You can also increase the highest frequency by lowering R22.