Fw: [motm] gate processor preview

2006-02-23 by Paul Haneberg

Sorry, this was meant for the group, not just for John

Paul H.


----- Original Message ----- 
From: "Paul Haneberg" <phaneber@...>
To: "John Loffink" <jloffink@...>
Sent: Wednesday, February 22, 2006 11:02 PM
Subject: Re: [motm] gate processor preview


> Okay, I'll be more specific
>
> The countersunk screw holes do not conflict with the .5U mounting hole 
> locations.
> You can use any combination of .5U and 1U spaced modules across rail 
> boundaries and at any locations.
> Here's all the numbers.
> If you still think it won't work, draw it.
>
> 1U=1.75"
> .5U=.875"
>
> Mounting Holes are centered .25 from the module edges.
>
> Assuming the left end of the Flat Rail is at 0"
> The following are the centers of the hole locations going along the X 
> axis:
>
> .25"  -  1U mounting hole
> .625  -  .5U mounting hole
> .875"  -  Countersunk hole for wood mounting
> 1.125"  -  .5U mounting hole
> 1.5"  -  1U mounting hole
> 2.0"  -  1U mounting hole
> 2.375"  -  .5U mounting hole
> 2.875"  -  .5U mounting hole
> 3.25"  -  1U mounting hole
> 3.75"  -  1U mounting hole
> 4.125"   -  .5U mounting hole
> 4.375"  -  Countersunk hole for wood mounting
> 4.625"  -  .5U mounting hole
> 5.0"  -  1U mounting hole
> 5.5"  -  1U mounting hole
> 5.875"  -  .5U mounting hole
> 6.125"  -  Countersunk hole for wood mounting
> 6.375"  -  .5U mounting hole
> 6.75"  -  1U mounting hole
> 7.25"  -  1U mounting hole
> 7.625"  -  .5U mounting hole
> 8.125"  -  .5U mounting hole
> 8.5"  -  1U mounting hole
> 9.0"  -  1U mounting hole
> 9.375"  -  .5U mounting hole
> 9.625"  -  Countersunk hole for wood mounting
> 9.875"  -  .5U mounting hole
> 10.25"  -  1U mounting hole
> 10.5"  -  Other end of Flat Rail
>
> 1U module boundaries would be at:
>
> 0.0"
> 1.75"
> 3.5"
> 5.25"
> 7.0"
> 8.75"
> and 10.5"
>
> .5U module boundaries would be at the above plus:
>
> 0.875"
> 2.625"
> 4.375"
> 6.125"
> 7.875"
> 9.625"
>
> The clearance at the edges of the countersunk holes is tight, but there is 
> no conflict.
>
> Try it, it works.
>
> Paul H.
>
>
>
>
> ----- Original Message ----- 
> From: "John Loffink" <jloffink@...>
> To: "'Paul Haneberg'" <phaneber@...>; <motm@yahoogroups.com>
> Sent: Wednesday, February 22, 2006 9:41 PM
> Subject: RE: [motm] gate processor preview
>
>
>> ?
>>
>> The countersunk screw holes conflict with some of the 0.5U mounting
>> locations.
>>
>> John Loffink
>> The Microtonal Synthesis Web Site
>> http://www.microtonal-synthesis.com
>> The Wavemakers Synthesizer Web Site
>> http://www.wavemakers-synth.com
>>
>>
>>> -----Original Message-----
>>> From: motm@yahoogroups.com [mailto:motm@yahoogroups.com] On Behalf Of 
>>> Paul
>>> Haneberg
>>>
>>> No, this assumes you could mount panels in 1.5U or .5U increments across
>>> 6U
>>> flat rail boundaries.
>>> The only assumption would be that you have a total of X*6U, (unless of
>>> course you cut down a flat rail or two)
>>>
>>> Paul H.
>>>
>>
>>
>>
>>
>> Yahoo! Groups Links
>>
>>
>>
>>
>>
>>
>>
>