Re: motm-100 q's

1999-10-06 by mark scetta

paul, i am still hearing a click that varies in amplitude on most or all of 
the samples. MOTM-100 is set to HOLD, speed & level are at 10.

my audio signal path is:

jp6 arpegg. in --> +15v preamp (set at 3:00) -->Y-split--> motm-100 IN & 
motm-110 VCA IN --> VCA out to mixer

my CV path is:

motm 100 OUT --> motm 110 CV   with CV mod pot at 10 and GAIN pot in the 
BIAS region

the clicks aren't loud, sort of like footsteps running along with the signal.

i have verified that the switch is wired correctly.

any further help is appreciated.
mark




>Message: 2
>    Date: Sat, 25 Sep 1999 15:17:42 -0500
>    From: "Paul Schreiber" <synth1@...>
>Subject: Re: motm-100 q's
>
>1) What is it that you are sampling? Also, be sure the switch is in HOLD,
>not TRACK
>(be sure the switch is wired correctly.
>
>The output of a S&H is *always* a CV, not audio. The input can be audio, but
>*not* the output.
>
>2) No, it is fixed at 7Hz.
>
>Paul S.
>
>-----Original Message-----
>From: mark scetta <n0nspaz@...>
>To: motm@onelist.com <motm@onelist.com>
>Date: Saturday, September 25, 1999 2:20 PM
>Subject: [motm] motm-100 q's
>
>
> >From: mark scetta <n0nspaz@...>
> >
> >
> >is is normal that the s&h, when sampling an external kb like my jp6,
> >produces highly audible clicks on every sample?
> >
> >
> >is it possible to vary the frequency of the vibrato? it seems to be fixed,
> >and the external clock doesn't seem to CV it.
> >
> >regards from providence
> >mark
> >
> >>
>
>
>
>___________________________________________________________________________ 
>____
>___________________________________________________________________________ 
>____

Attachments

Move to quarantaine