2001-09-29 by Dave Hylander

I think your talking about one of Jim's modules , and it did turn out to be 
a reversed polarity.  I had a similar problem a bad timer IC that was 
pulling down the supply voltages across the modules powered by the same PS.

Check your connections for polarity.  If you have a DVM, check the voltages 
with only the suspect module in attached.  If you have a DVM, call Paul, 
and he can walk you through diagnosing the faulty component.

dave

At 01:05 AM 9/29/01 -0400, you wrote:
>My guess too. There was a post a couple of months ago involving an 800 (?)
>with a similar behavior -- a few of us suggested looking into these areas,
>but I don't remember ever hearing back as to what the problem was (ever find
>out?).