There should be no added slop in your cabinet design. The panels are mounted on exact 1U increments. 1U is exactly 1.75". The gaps between 2 panels happens because the panels are cut about 0.025" narrower than the full width. Now if you want to add separators, all bets are off. You'll have to add the thickness of the separators in and spread the holes out. But it will still be a problem between 1U and 2U modules, because there will be twice the thickness of separators to fit 2 1U panels into a width that formerly held a single 2U panel. For this reason, I don't think separators that fit over the ends and spread the modules are practical. You can't spread the holes that hold a 2U panel, and those holes won't be wide enough to deal with the extra thickness of 2 1U modules. So you would end up with a cab that couldn't freely interchange the positions of 1U and 2U modules, and what's modular about that? Moe --- In motm@y..., drq48423@y... wrote: > I just KNOW somebody here has already dealt with this problem, so here > it goes... > > Here I am, doing the math for a 24U cabinet. I just got my order for > 300 zinc hex drive inserts from McMaster.com (they're cheap AND fast > too!) and I'm ready to go. 24U = 42 inches internal, check. With 3/4 > in. wood (of a type yet to be determined) we get an external length of > 42 + 1 and 1/2 in. = 43 1/2 inches, check. And two 1/2 in. thick pine > strips on the inside horizontal, to hold the inserts (huh...huh...I > said inserts ;-) > > Now comes the tricky part; figuring the *slop factor* (MOTM-spec is > 0.015 in. or, 1/64 in.). If we assume 24 *slop gaps*, then 24 times 1/ > 64 in. = 24/64 in. = 3/8 inch! Yikes! Can this be right? That's a lot > of slop. So, should I add 3/8 in. to the overall length? I was planning > to set the inserts by setting a '800 in the completed box, mark the > holes, drill and set the inserts, bolt the '800 down, insert 1/64 in. > spacer between it and a blank 1U panel, mark the holes, ect. so I'll > need to know the correct length beforehand. I see there's enough play > in the mounting holes on the panels to give me some wiggle room, so I > guess my question is, am I being too anal about this *slop factor* > stuff? > > Somebody mentioned something about plastic strips for use as visual > separators between modules (plastistruct?), ala Moog. I need to look > into that and I'm too lazy to look it up in the archive ;-) > > Chuck > being anal AND lazy
Message
Re: gaps in MOTM cabinets
2001-03-21 by mate_stubb@yahoo.com
Attachments
- No local attachments were found for this message.