Are internal demo songs OK? Do they play?
Anyhow, you can try following.
I would do this:
- if machine was not used for longer time, leave it switched on through all day as long as possible, but keep eye on it all the time (danger of fire ???)
- reset (see below)
- go through test routines (see below)
- check, clean and reseat all connectors inside with contact spray
- reseat all IC's in sockets (be very careful not to bend or break pins)
- measure PSU voltages if they conforms with the spec
- maybe change electrolytic caps in PSU, after so many years maybe they need to be replaced
- check internal RAM battery, if it's dead, replace it
- load the original factory data from the ROM card if you have it, if not, send some proper SysEx data through MIDI, be it original factory set or other
Good luck!
Daniel Forro
P.S.: Isn't this KORG group?
--------
Roland D5 Test Mode
Before conducting the tests, make sure that the pedal and memory card are not connected.
Entering test mode:
1 - Press the MODE repeatedly until the ROM PLAY LED lights. The unit is now in ROM PLAY mode.
2 - Press and hold the EXIT and EDIT and then press the ENTER; the display shows the following indicating that the unit is in test mode.
Select Mode
A/B + ***button
During the test mode the following buttons serve as test selector button.
A/B+NUMBER1 BATTERY TEST
A/B+NUMBER2 DA ADJUST
A/B+NUMBER3 A/D, SWITCH TEST
A/B+NUMBER4 LED TEST
A/B+NUMBER5 MEMORY TEST
A/B+NUMBER6 CARD TEST
A/B+NUMBER7 TUNE TEST
A/B+NUMBER8 MIDI TEST
A/B+BANK1 KEYBOARD TEST
Press and hold the A/B and then press the DISP: test routine will proceed to the next each time DISP is pressed.
To exit the test mode, turn off and on the unit, or while holding the A/B press the INT/CARD.
------------
To check your Pitch and Mod levers go to test 3 which is the A/D and Switch test. If you press the pitch to the right it should show in the display an increase from 000 to +127. The other direction should go opposite - 000 to -127.
With Mod lever it should go from 000 at rest to 127 when pushed forward.
You can also check your panel switches and hold pedal inputs.
-----------------
There doesn't seem to be a 'normal' reset procedure however Roland has a section in the service manual called 'Setting Data'. Here it is...
Setting Data
If the tone RAM (main board IC17) has lost the tone data due to battery replacement or the tone RAM itself has been replaced, take the following procedure.
1 - Enter test mode.
2 - Holding donw the A/B, press the BANK 7; the following settings will return to the factory value:
SET UP
MIDI
TUNE/FUNCTION
KEY TRANSPOSE
To recover Patch, Timbre and Internal tone to the factory setting, proceed to the following steps.
1 - Enter test mode.
2 - Insert the memory card (D-5 FACTORY PRESET CARD) into the MEMORY CARD slot.
3 - Holding down the A/B, press BANK 6. The display will show the following message, and the recovery process is completed.
FACTORY PRESET
Load Completed
-----------------------
Roland D5 Test Mode
Before conducting the tests, make sure that the pedal and memory card are not connected.
Entering test mode:
1 - Press the MODE repeatedly until the ROM PLAY LED lights. The unit is now in ROM PLAY mode.
2 - Press and hold the EXIT and EDIT and then press the ENTER; the display shows the following indicating that the unit is in test mode.
Select Mode
A/B + ***button
During the test mode the following buttons serve as test selector button.
A/B+NUMBER1 BATTERY TEST
A/B+NUMBER2 DA ADJUST
A/B+NUMBER3 A/D, SWITCH TEST
A/B+NUMBER4 LED TEST
A/B+NUMBER5 MEMORY TEST
A/B+NUMBER6 CARD TEST
A/B+NUMBER7 TUNE TEST
A/B+NUMBER8 MIDI TEST
A/B+BANK1 KEYBOARD TEST
Press and hold the A/B and then press the DISP: test routine will proceed to the next each time DISP is pressed.
To exit the test mode, turn off and on the unit, or while holding the A/B press the INT/CARD.
------------
To check your Pitch and Mod levers go to test 3 which is the A/D and Switch test. If you press the pitch to the right it should show in the display an increase from 000 to +127. The other direction should go opposite - 000 to -127.
With Mod lever it should go from 000 at rest to 127 when pushed forward.
You can also check your panel switches and hold pedal inputs.
-----------------
There doesn't seem to be a 'normal' reset procedure however Roland has a section in the service manual called 'Setting Data'. Here it is...
Setting Data
If the tone RAM (main board IC17) has lost the tone data due to battery replacement or the tone RAM itself has been replaced, take the following procedure.
1 - Enter test mode.
2 - Holding donw the A/B, press the BANK 7; the following settings will return to the factory value:
SET UP
MIDI
TUNE/FUNCTION
KEY TRANSPOSE
To recover Patch, Timbre and Internal tone to the factory setting, proceed to the following steps.
1 - Enter test mode.
2 - Insert the memory card (D-5 FACTORY PRESET CARD) into the MEMORY CARD slot.
3 - Holding down the A/B, press BANK 6. The display will show the following message, and the recovery process is completed.
FACTORY PRESET
Load Completed
-----------------------
On Apr 8, 2015, at 11:03 PM, Vincenzo Vincenzo sarvamala@... [korgpolyex] wrote:
hello Gordon,
thanks for the advice but in addition to the problem of the display incomprehensible Roland D5 does not sound ..
then suddenly everything himself begins to make strange sounds without the pressure of the keys and the LEDs do not light and pressing the function keys nothing happens ..
according to you can be burned CPU or some other integrated?