Korg Poly800/EX800 Users group photo

Yahoo Groups archive

Korg Poly800/EX800 Users

Index last updated: 2026-04-28 23:27 UTC

Message

Re: question for HAWK-800 owners

2009-07-06 by korgpolyex800

Hi Dave,

Yes, all possible combinations of the harmonics would be available using just the one parameter instead of four.

Sorry to hear about the bad currency rates between US and AR.

Mike


--- In korgpolyex@yahoogroups.com, "David Mochen" <davidmochen@...> wrote:
>
> Sorry if I am not getting this well, but would this allow combinations like this:
> 
> 16        8        4        2
> ON       OFF    OFF    ON
> ON       OFF    ON     ON
> OFF      ON     ON     OFF
> 
> where harmonics are not "incrementally" switched on? Settings like the above I have actually used for many patches (for instance, chossing a "square" wave and having only harmonics 16 & 2 on allows for some bell-like sounds).
> 
> BTW, I yet have to post a video and explanation about some very irrititating behavior my Poly has been experimenting recently (related to pitch). And I have been struggling with incomes and also rocketing US dollar exchange rates here in Argentina (1 dollar = 3.8 AR$; average salary being around 3K AR$) that have put a temporary gag on my plans to go Hawk 800. Hope to get my Poly fixed soon and then, soon, my Hawk.
> 
> thanks in advance
> 
> Dave
> 
> 
> 
>   ----- Original Message ----- 
>   From: Daniel Forro 
>   To: korgpolyex@yahoogroups.com 
>   Sent: Sunday, July 05, 2009 1:16 PM
>   Subject: Re: [korgpolyex] question for HAWK-800 owners
> 
> 
> 
> 
> 
>   Nice, just maybe this different order would be more easy to remember 
>   and to use than yours purely binar:
> 
>   16' 8' 4' 2'
>   08 = X
>   04 = X
>   02 = X
>   01 = X
>   12 = X X
>   10 = X X
>   09 = X X
>   06 = X X
>   05 = X X
>   03 = X X
>   14 = X X X
>   13 = X X X
>   11 = X X X
>   07 = X X X
>   15 = X X X X
> 
>   I left your original numbers for comparison, but of course numbering 
>   should go from 01 to 15 again.
> 
>   Daniel Forro
> 
>   On 5 Jul 2009, at 11:49 PM, korgpolyex800 wrote:
> 
>   > Hi HAWK-800 owners,
>   >
>   > I have a question for you all.
>   >
>   > I am about to put LFO/EG control of DCO harmonics into the 
>   > HAWK-800. However, due to the reduced number of available 
>   > parameters, I am thinking about combining the harmonics parameters 
>   > into one parameter. That is, parameters 13 to 16 would all be 
>   > combined into 13. And, parameters 23 to 26 would be combined into 
>   > 23 also.
>   >
>   > Then, parameters 13 and 23 would have available values 0 through 
>   > 15. 1 through 15 would engage the DCO harmonics in a fixed manner 
>   > using binary math to determine the actual engaged harmonics.
>   >
>   > So the harmonics would be engaged as follows where X means the 
>   > harmonic is ON:
>   >
>   > 16' 8' 4' 2'
>   > 01 = X
>   > 02 = X
>   > 03 = X X
>   > 04 = X
>   > 05 = X X
>   > 06 = X X
>   > 07 = X X X
>   > 08 = X
>   > 09 = X X
>   > 10 = X X
>   > 11 = X X X
>   > 12 = X X
>   > 13 = X X X
>   > 14 = X X X
>   > 15 = X X X X
>   >
>   > This arrangement provides a couple of advantages. First, it frees 
>   > up the next three parameters for other purposes. Second, it allows 
>   > MIDI and user parameter control of the harmonics in one parameter 
>   > which will provide real time improvement over control of the 
>   > harmonics.
>   >
>   > Most important though, the next three parameters will be able to be 
>   > used for new harmonic controls.
>   >
>   > Parameter 14/24 will be the LFO or EG3 modulation selector.
>   > Parameter 15/25 will be the harmonic order selector.
>   > Parameter 16/26 will be the harmonic velocity sensitivity selector.
>   >
>   > I'll go into the details of those later but right now, is everyone 
>   > OK with dropping the single harmonic selector parameters and using 
>   > a combined parameter for all four harmonics?
>   >
>   > Mike.
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.