2005-09-30 by elmacaco

can;t hurt to try, I would check for cold solder joints as well.
  ----- Original Message ----- 
  From: Steve Adam 
  To: emax@yahoogroups.com 
  Sent: Friday, September 30, 2005 3:39 PM
  Subject: RE: [emax] Re: Emax keys


  Does the diode have any bearing on the velocity senstivity? I ask because I
  have one key which starts defaulting to velocity value 1 about ten minutes
  after the machine warms up. Cleaning makes no difference (no surprise
  really) and sending it for repair is going to be too expensive to justify.
  But if there's any chance a simple replacement diode will do the trick, I'm
  happy to give it a try.

  -----Original Message-----
  From: emax@yahoogroups.com [mailto:emax@yahoogroups.com]On Behalf Of
  Chris Strellis
  Sent: 23 September 2005 10:02
  To: emax@yahoogroups.com
  Subject: [emax] Re: Emax keys


  Hi,

  The contacts are definately wires.  I had a non-triggering key on my
  Emax SE and no amount of cleaning fixed it.  It turned out to be the
  glass diode for the key - it had actually been shattered in transit.
  I replaced it with a 1N4148 and everthing came good :D

  Cheers

  Chris






  Emax and Emax II User's Group Website

  http://www.silveriafamily.com 



  SPONSORED LINKS Electronic instrument  Emax  Synthesizer music  
        Electronic music  Music sampler  Electronic musical instrument  


------------------------------------------------------------------------------
  YAHOO! GROUPS LINKS 

    a..  Visit your group "emax" on the web.
      
    b..  To unsubscribe from this group, send an email to:
     emax-unsubscribe@yahoogroups.com
      
    c..  Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service. 


------------------------------------------------------------------------------



[Non-text portions of this message have been removed]

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.