sounds like you have lost the 5v connection
the lcd uses 5v the cf card reader uses 5v and the floppy uses 5v
i would check the 5v rail on the psu
----- Original Message -----
From: David Sotnick
To: emax@yahoogroups.com
Sent: Monday, February 17, 2014 4:25 PM
Subject: [emax] Diagnosing non-functional Emax
Hi all,
Now it's my turn… I'm sad to report that my beloved Emax SE Rack which I upgraded to SCSI and slim floppy is no longer booting.
Symptoms are: PSU voltages look good at the drive power connector. All LEDs on the front panel come on at power-on except load and enter. No LCD display and no floppy or CF reader activity. :-(
I have re-seated all cables but have not yet removed and re-seated any socketed ICs. It has just been sitting in a rack, so nothing has been jostled.
Any suggestions on where to start?
-Dave
p.s. even more frustrating: I missed out on a $60 working Emax SE on a local Craig's list ad which posted the day before I discovered my Emax was dead. :-(
No virus found in this message.
Checked by AVG - www.avg.com
Version: 2014.0.4335 / Virus Database: 3705/7098 - Release Date: 02/16/14Message
Re: [emax] Diagnosing non-functional Emax
2014-02-17 by jammie
Attachments
- No local attachments were found for this message.