Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Re: SYX - Presets for E-Mu Vintage Keys ?

2009-08-15 by rpcfender

Peter

> However, problems occur exactly at the points you described at negative values and also at switching filter modes, and values above 127 etc..
> 
> So a workaround is to assign two knobs for minus values or for value ranges above 128, e.g.:
> 
> - left pan (-7) and right pan (+7): 2 knobs for each instrument - total 4 knobs for panning)
> - 4 individual knobs for presets for 0-127, 128-255, 256-384, 384-512

Normally these should be switched by Banks which is CC0 and CC32 that you could assign to switches, but in your case you only get 128 presets accessible at one time via Midi.
You have to build a Program map, for example assigning preset 400 to slot 23 then send midi program change 23 and you get preset 400
manual p21
page 108 talks about it having 6 banks of 64  presets, but I can't see if you can select the banks and then send preset select message.

A lot of the useful parameters are already mapped to CC , see page 116
This might be enough?

> I prefered not to mess with the sysex this time.
> Maybe its good enough like this. If you have a nicer solution i would appreciate any comments.

All the best
Royce