Message

Re: Monitoring/Filtering Problem...

2006-02-27 by Gilles Coudert

Try this:

1. Switch on the sampler.
2. Format a HD floppy.
3. Save the Operating System onto it (Disk - Save - Operating System)
4. Tweak the blank 'Test Program' so the filter cutoff setting is +25 
or whatever you want it to be. Adjust anything else you want, to 
create a default program.
5. Save the Test Program to the floppy (without wiping it first!)
6. Reboot the sampler with the floppy inside the drive - you'll have 
to do this every time, but you won't have to tweak the cutoff 
frequency every time.

Hope this helps,

Gilles