Yep, sounds about right. WT ----- Original Message ----- From: "xylofoam" <lars.frisk@...> To: <Simmons_Drums@yahoogroups.com> Sent: Friday, October 07, 2011 3:57 PM Subject: Re: [Simmons Drums] Voltage conversion of the MTM transformer... ? I managed to get it going... It seemed to have been the coating on the wires had too good insulating properties... :-) Btw. What's the fuse when set to 240V? Is it 1A/250V? (When set to 110V it had a 2A/250V fuse) Cheers // Lars --- In Simmons_Drums@yahoogroups.com, "WT" <waveterm@...> wrote: > > Unfortunately no, I bought one a long time ago but they don\ufffdt seem to have > it any longer. > > WT > > ----- Original Message ----- > From: "xylofoam" <lars.frisk@...> > To: <Simmons_Drums@yahoogroups.com> > Sent: Monday, October 03, 2011 3:50 PM > Subject: Re: [Simmons Drums] Voltage conversion of the MTM transformer... > ? > > > Yes, that's exactly what I thought as well... > Do you know what the outputs are from the secondaries, or perheps even > what > an Elfa replacement transformer would be ? > > cheers > // Lars > > --- In Simmons_Drums@yahoogroups.com, "WT" <waveterm@> wrote: > > > > Looking at the schematics, you only need to have black and orange ( or > > pink > > for 220V ) connected to the fuse/mains switch. > > > > This should work. If it doesn\ufffdt the transformer could be toast. You can > > get > > a new one at Elfa. > > > > WT > > > > ----- Original Message ----- > > From: "xylofoam" <lars.frisk@> > > To: <Simmons_Drums@yahoogroups.com> > > Sent: Monday, October 03, 2011 1:58 PM > > Subject: Re: [Simmons Drums] Voltage conversion of the MTM > > transformer... > > ? > > > > > > > Hehe :-D > > > > > > // L > > > > > > --- In Simmons_Drums@yahoogroups.com, jesper <jesper@> wrote: > > >> > > >> xylofoam skrev 2011-10-03 10:20: > > >> > Hi all, > > >> > > > >> > I'm trying to convert the original transformer in my MTM unit from > > >> > 110V > > >> > to 240V... According to the service manual the transformer supports > > >> > all > > >> > voltages on the primary core (all colours match the schematics > > >> > (black:0V, brown:100V, white:110V, pink:220V and orange:240V)), but > > >> > when > > >> > I reconfigure the tranfsformer to EU (240V) I get absolutely > > >> > NOTHING > > >> > on > > >> > either of the secondaries?! > > >> > What am I doing wrong? According to the schematics there is only > > >> > ONE > > >> > primay core, but are there really TWO that needs to be in serial, > > >> > or > > >> > ? > > >> > > >> Sell it to me instead. I have 110-feeds to spare. :D > > >> > > >> -- > > >> electronically yours, jesper > > >> > > >> - -- --- ---- ----- ---- --- -- - > > >> www.electronic-obsession.se > > >> > > > > > > > > > > > > > > > ------------------------------------ > > > > > > Yahoo! Groups Links > > > > > > > > > > > > > > > > ------------------------------------ > > Yahoo! Groups Links > ------------------------------------ Yahoo! Groups Links
Message
Re: [Simmons Drums] Voltage conversion of the MTM transformer... ?
2011-10-07 by WT
Attachments
- No local attachments were found for this message.