Hi Ricardo / Dieter Am 23.10.2012 16:36, schrieb yahoo@doepfer.de: > I think he is right. The Meanwell PSU is obviously a single PSU (i.e. one > voltage output only, not two like the A-100PSU2). In this case the -V output > of the Meanwell has to be connected to GND of the A-100 system. You may use > e.g. a free GND terminal at the bus board. The +V of the Meanwell (= +5V) > has to be connected to the unused +5V terminal of the A-100 bus board. Thank you for the correction! I have a +/-15V supply from Meanwell and was transfering the connection info from there. I should have had a look at the datasheet before: http://www.jameco.com/Jameco/Products/ProdDS/123290.pdf At page 2 you can see that the 5Volts are between -V and +V. Florian -- http://fa.utfs.org/
Message
Re: [Doepfer_a100] Re: Please help! Installing +5v switch inside G6 case for firing up tube modules
2012-10-23 by Florian Anwander