thanks everybody yup the earth one i recognized for only metal case. i building one out of wood. ah the supplyboard is getting quite close to the one side of the case. hope its getting not to hot! best felix > > hi >> >> befor i blow up anything. >> >> am i right i just dont have to care which cabel from the external 15V >> Transformer >> goes to the diy powersupply board? >> >> the transformer got a red and a white stripe but the board just got >> to pins for 15V AC. >> >> i will put some xlr connection inbetween the case also. >> >> best >> felix > >As it's AC you don't have to pay attention to the polarity. But pay >attention to connect the cables to the right terminals of the power supply >board as shown in the manual (both terminals are labelled "15V AC"). Do not >use the terminal with the shield/earth symbol for the transformer. Some >customers fried their transformer by using this terminal to connect the >transformer. The shield/earth terminal is used only in case of a metal >housing to ground the housing. > >Best wishes >Dieter Doepfer > > [Non-text portions of this message have been removed]
Message
Re: AW: [Doepfer_a100] doepfer diy set 1
2011-11-15 by istari
Attachments