Paul, Are you suggesting that the errors in Jon Cones results might be deliberately biased towards his inks? I personally wouldn't trust anything that he publishes until it is verified by a independant source such as your own. Jon Cones pruducts have never quite come up to his promises along with his after sales support. I am happy with the MIS FSN for the time being, my Epson 2200 is also producing some fine B/W prints. Keep up the good work. Barry --- In DigitalBlackandWhiteThePrint@y..., "Paul Roark" <paul.roark@v...> wrote: > Robert, > > You wrote: > > >Finally a manufacturer published actual test results. > > It is good to see some data. I've always liked the fact that MIS published > its RIT test results for the MIS Archival inks. > > It looks like there may be an error in the MIS FS delta E calculation in the > fade results Cone Editions released. The FS K faded less than the Portfolio > black, yet is listed as having a higher delta e. > > I'm also not sure about note 3 on the "Test Condition." It says, > "Lightfastness: Irradiation UV (Xe) 10,000 Kj/m2/200 hours." > > If the lamp was strong UV, then I wonder if the results correlate well with > actual lighting. Most of us are oriented to indoor display, where the UV > from fluorescent lights or window-filtered (thus no deep UV) light is the > main problem. Unlike the outdoor signage market, I don't think we have that > much of a UV problem with our prints. > > I'm a little surprised that the carbon sepia did not do better. I would > have thought that an ink that was supposed to be pure carbon would fade less > than inks that have some color pigments in them to get the tones that are > popular. > > I'll run my own tests as samples are provided. > > Paul > http://www.PaulRoark.com > ______________________________________ > > From: piezography3000@y... > Reply-To: piezography3000@y... > Date: 7 Nov 2002 03:12:17 -0000 > To: piezography3000@y... > Subject: [piezoBW] New file uploaded to piezography3000 > > > Hello, > > This email message is a notification to let you know that > a file has been uploaded to the Files area of the piezography3000 > group. > > File : /400 Hour Xenon tests/preliminary-xenon.pdf > Uploaded by : piezobw <piezobw@c...> > Description : 400 hours on EPSON EAM > > You can access this file at the URL > > http://groups.yahoo.com/group/piezography3000/files/ > 400%20Hour%20Xenon%20tests/preliminary-xenon.pdf > > [cut and paste the last part of the URL]
Message
Re: PiezoTone Fade Data (was [piezoBW] New file uploaded to piezography3000)
2002-11-07 by flyfishingusa2002
Attachments
- No local attachments were found for this message.