I was thinking about the full configuration using 16 potentiometers. 8 input presets and 8 input attenuators. That would be enought to make a nice sequencer if you could read the two banks of pots as voltage values. There is actually a trick we could use to keep normal function but read the pots as two banks of 8. It requires one port line and input jacks with normalized switches. Use the port line to switch a 10 volt reference from the bank of 8 offset pots (where it is normally connected) to all the input jacks switch inputs. This shuts off the offset pots and allows the 8 attenuator pots to be read as voltage values, while still serving as attenuators under normal circumstance (something plugged into the input jack). The offset pot summer values would change to 200K, instead of 301K if the offset pots were connected to +15V. Just thought I'd mention it in case Harry thinks it is worth the extra effort.
Message
A trick to read the input pots as 16 voltage values
2006-03-22 by Grant Richter
Attachments