Hi folks, I managed to fix it with a little trial and error. If you feed the reset patch cord vis a .01 ceramic disc capacitor the problem is resolved. Cheers, TOM --- In vintagesynthrepair@yahoogroups.com, "Quazimodo" <noddyspuncture@...> wrote: > > Thanks for the quick reply Mike. But no, the ground lug on the reset sockets isn't actually wired! And when I touch the 'live' tip to a known ground point it still doesnt reset! > Strange eh? > Any other ideas would be much appreciated...;c) > > > > --- In vintagesynthrepair@yahoogroups.com, Mike <mrjdevries@> wrote: > > > > Korg uses s-trig on most vintage stuff. > > When you pull the jack out, the tip probably makes contact with ground, resetting the sequencer. > > You could verify this by touching the tip of the cable against the chasis, like a jack socket locknut. Does that reset the sequence? > > > > (I don't own a sq10, so the above is speculation) > > > > If the above holds true, then there may be a workaround, but I think it may involve a rotary switch and a DIY box with a bunch of cables. > > > > Cheers > > Mike > > > > Sent from my Apple ][e > > > > On 16/09/2011, at 10:36 PM, "Quazimodo" <noddyspuncture@> wrote: > > > > > Hi everyone, > > > > > > I have a Korg SQ-10 sequencer. I am trying to sequence different patterns of different lenghts by patching the reset whilst the sequence is running. So say for example I want to have an eight note sequence and then pull the cord and put it into the seventh channel to make the next run a seven note sequence, I am finding that as I pull the cord and change sockets - the sequence is interrupted and starts from the beginning...! Not the desired effect. Does anyone know why this is happenng and if there is a work around fix for it..? > > > > > > Cheers, > > > TOM > > > > > > > > >
Message
Re: Korg SQ-10 anomaly..? FIXED..!!!
2011-09-16 by Quazimodo
Attachments
- No local attachments were found for this message.