Yahoo Groups archive

Vintage Synth Repair

Index last updated: 2026-04-28 23:41 UTC

Message

[vintagesynthrepair] Re: Crumart Trilogy replacement power transformer

2011-06-21 by Malte Rogacki

At 12:46 Uhr +0000 21.06.2011, Boddington wrote:
> The working transformer from the Stratus produces 20V AC off the
>secondary but
> note that the PSU, while being the same pcb on paper, has less jumper pins on
> J1 & J2. The Trilogy's transformer must have produced more voltage on the
> secondary than this Stratus' does.

Why must the Trilogy's transformer have produced more voltage?

Does the 20V figure apply to both secondaries?

How did the transformer of the Trilogy check out on its own? Does it blow
the fuse?

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.