--- In vintagesynthrepair@yahoogroups.com, "Gil" <gilwe@...> wrote: > > > I was recapping the power supply in my E-II and mistakenly fiddled with all four trimpots on the PS circuit, trying to set the correct voltages. I found that only two of them affect the voltage rails (-15v/+15v/+13.2v) but the other two don't affect the voltage at all. > > I now have no idea how these other two trimpots (marked as R109 and R110 on the schematics) should be set and am afraid that being set wrongly I will damage the E-II. > > Does any of you have any idea what they do and how they should be set, or have an access to the calibration procedure of the E-II ? > > here are the two trimpots as appearing on the schematics: > http://www.fileden.com/files/2006/10/13/285304/E-II%20PS.JPG > > Thanks very much !! Those pots are on the High-voltage DC side of the power supply These will more likely affect switching frequency of the supply and not any output level The +12 and -15 will be fixed voltages. >
Message
Re: Help calibrating Emulator II power supply... Thanks in advance !
2011-03-20 by Scott
Attachments
- No local attachments were found for this message.