For what it's worth I too would suspect the new pots are not the correct value. From your description I would hazard a guess that the new pots are out by a factor of 10; so for example if the original pot had a value of 1M Ohm the new pot was 100k Ohms. This would account for the reduction of around 10 in your decay time. I'd check the old pots against the new using a multimeter. Regards Brian G3OYU From: vintagesynthrepair@yahoogroups.com [mailto:vintagesynthrepair@yahoogroups.com] On Behalf Of alexandrodeexu Sent: 20 May 2010 5:13 To: vintagesynthrepair@yahoogroups.com Subject: [vintagesynthrepair] Roland SH101 envelop generator Hi I have a problem with Roland SH101,after exchange of pots in VCF and Envelop to brand new,all envelop generator settings became wrong,maximum time for Attac,Decay & Realise is about 1.5s ( must be 10s ),And also there's no effect from sustain pot if I stay high decay parameter. Thanx.