No. the source of the leakage is within your polysix, the ground wire merely drains it away (to where ?) On 31-08-18 19:13, Peter Foley petereugenefoley@gmail.com [PolySix] wrote: > With the grounded cable, I\u2019m not measuring any AC anymore. Would this > mean it could be an issue in my mains? My house was built about a > hundred years ago... > > On Aug 31, 2018, at 11:52, Ben Stuyts yahoo@stuyts.nl > <mailto:yahoo@stuyts.nl> [PolySix] <PolySix@yahoogroups.com > <mailto:PolySix@yahoogroups.com>> wrote: > >> Peter, this solves the grounding problem. But not the leakage which >> should not happen. (At least, not in that amount.) There is still a >> problem lurking inside there. >> >> >> Ben >> >> >>> On 31 Aug 2018, at 14:52, Peter Foley petereugenefoley@gmail.com >>> <mailto:petereugenefoley@gmail.com> [PolySix] >>> <PolySix@yahoogroups.com <mailto:PolySix@yahoogroups.com>> wrote: >>> >>> >>> >>> Putting a grounded power cable in the synth did the trick! >>> >>> On Aug 31, 2018, at 07:20, Malte Rogackigacki@gacki.sax.de >>> <mailto:gacki@gacki.sax.de>[PolySix] <PolySix@yahoogroups.com >>> <mailto:PolySix@yahoogroups.com>> wrote: >>> >>>> One possible suspect could be the spark killer. >>>> If I remember correctly this was also a problem with some Akai devices? >>>> >>>> And yes, please be very careful. >>>> >>>> In theory, if the grounding isn't damaged (and the house grounding >>>> is ok), >>>> something like this should not be possible at all. >>>> >>> >>> >> > -- Met vriendelijke Groet, Simon Claessen drukknop.nl
Message
Re: [PolySix] Polysix frying mixer channels
2018-09-01 by simon
Attachments
- No local attachments were found for this message.