Discussion about the Korg PolySix synthesizer group photo

Yahoo Groups archive

Discussion about the Korg PolySix synthesizer

Index last updated: 2026-04-28 23:40 UTC

Message

Re: [PolySix] P6 MG Oddity

2018-03-01 by <backshall1@bellsouth.net>

Since the Mod switch and the Waveform switch depend on the P12, P13 signals from KLM-367 to the panel boards, maybe this is a connection problem on CN06 (the blue wires) and not a problem on the clone board.
Don B.

From: jimpster@me.com [PolySix] 
Sent: Thursday, March 1, 2018 5:22 AM
To: PolySix@yahoogroups.com 
Subject: Re: [PolySix] P6 MG Oddity

  
Ok thanks, I'll be aware of that when following the service manual. 


Just to note what you mentioned about PWM, I have indeed now noticed that MG behaves differently if I select Waveform PWM, on this wave I do get some MG VCO Modulation but still with some VCF.

With Saw or PW Waveform there is no MG VCO Modulation (as my original post)