Am 22.12.2016 um 12:00 schrieb ninonine@xs4all.nl [PolySix]:
"A voltage composed of the manual delay control, CV1 and CV2 is
available at the CV out socket, e.g. to control an external clock
suppression filter as the A-188-2 is not equipped with such a filter
(same as for the A-188-1 <http://www.doepfer.de/A1881.htm>)."
> Thanks for the cap reduce info, will look into that. One could alsoThat "noise" is intended. See http://www.doepfer.de/A1882.htm
> bypass the effects entirely or put a LM13700 instead all are options
> subject to taste. I wonder btw did doepfer fix the BBD clock generator
> noise in the (tapped) bbd A-100 modules? This might also be a good
> Question for the Doepfer group that we also post in :)
"A voltage composed of the manual delay control, CV1 and CV2 is
available at the CV out socket, e.g. to control an external clock
suppression filter as the A-188-2 is not equipped with such a filter
(same as for the A-188-1 <http://www.doepfer.de/A1881.htm>)."