Hi, I need your help, guys. Afeter troubleshooting KLM367 with slight battery leakage, replacing the battery, the IC at the left and the electrolitic capacitor at the right, I find that the VCOs goes heavily modulated by a fast sine wave not coming from the MG nor from the bender/mod. Also unison mode is not selectable. I've double checked the continuity of the traces in the damaged area a few times with a multimeter and everything looks fine. Any clue?. Thanks for your help in advance.
Message
Unison not selectable and fast modulation on VCO not coming from MG
2014-08-03 by moogchild@yahoo.es